| Communication Module CN-Type CC-Link-Slave
The COM-CA-CCS and COM-CN-CCS communication modules are meant for integration into field devices or programmable controllers. Via a Dual-port-memory access, these modules can be integrated directly into the application program.
|
|
|
|
|
|
|
| Facts at a glance: |
| Fast "Time to Market" |
| Cheaper than own development |
| Easy to configure |
| MFP3 technology |
|
|
|
| Product
|
COM-CN-CCS
|
|
|
|
| Description
|
Communication Module CN-Type
|
| CC-Link-Slave
|
|
|
|
| Card format
|
COM-C
|
|
|
|
| Bus interface
|
Dual-Port-Memory
|
|
|
|
| Dual-Port-Memory
|
8 KByte
|
| Interrupt
|
Yes
|
| Connector
|
Female strip connector 2x25-pin, grid 1.27
|
|
|
|
| CC-Link Communication
|
|
|
|
| Type
|
Slave, Remote Device Station
|
| Stations
|
max. 4
|
| Input data
|
max. 128 bits, max. 16 words (with 4 stations)
|
| Output data
|
max. 128 bits, max. 16 words (with 4 stations)
|
| Connection
|
Polling
|
|
|
|
| CC-Link interface
|
|
|
|
| Transmission rate
|
156 kbps / 625 kbps / 2.5 Mbps / 5 Mbps / 10 Mbps
|
| Controller
|
MFP3
|
| Interface
|
EIA Standard RS-485, potential free
|
| Connector
|
Female strip connector 2x15-pin, grid 1.27
|
|
|
|
| Diagnostic interface
|
TLL, non-isolated
|
|
|
|
| Connector
|
via female strip connector
|
|
|
|
| Display
|
SYS, COM
|
| Operating voltage
|
3,3 V ±5 % / 450 mA
|
| Operating temperature
|
0 °C ... 60 °C
|
| Dimensions (L x W x H)
|
70 x 30 x 20 mm
|
| Weight approx.
|
24 g
|
| CE sign
|
Yes
|
|
|
|
| Related products
|
Device driver Windows DRV-WIN
|
| Device driver Linux DRV-LNX
|
| C functions library, toolkit DRV-TKIT
|
| Device driver Windows CE
|
|
|
|
|
|
|