CT-N816
CorNet ARCNET Diagnostic Hub 8 Port Twisted Pair
|
Description
This is an ARCNET hub with diagnostic LEDs and linking ports. The CT-N800 series of
hubs was created to fill a need for an ARCNET hub with additional diagnostic capabilities
for tracking down reconfiguration problems without resorting to the complexity and cost
of an "Intelligent Hub". These hubs are built to withstand a wide range of temperature
and power line voltage swings. The hubs maintain full output levels even when
running at maximum temperature and data traffic loads.
This stability is provided through the use of a
switching regulator in the power supply and attention
to detail in the output driver section. The switching
regulator produces less heat and withstands brownouts
better than a linear regulator. Proper thermal design
ensures that heat produced in the output drivers is
dissipated via convection air currents in any acceptable mounting position.
|
|
OPERATING ENVIRONMENT
|
Power:
|
120 VAC +6%/- 10% @ l60 mA
240 VAC +6%/- 10% @ 80 mA
50 Hz or 60 Hz
|
|
Operating Temperature:
|
0°C to 55°C
|
|
Humidity:
|
5% to 80% (non-condensing)
|
ARCNET LAN INTERFACE
|
Transmit level:
|
15.4 Vp-p
|
|
Receive Sensitivity:
|
3.0 Vp-p
|
|
Connectors:
|
RJ11
|
PHYSICAL SPECIFICATIONS
|
Height:
|
2.75 inches
|
|
Width:
|
8.5 inches
|
|
Depth:
|
7.5 inches (including connectors)
|
|
Height:
|
5 pounds
|
Included with the hub are two mounting brackets and four bolts for attaching the brackets to the hub. A link cable
and one terminator are included for expanding the hub configuration to add more ports or to connect hubs with
different types of media. A detachable power cord is also included.
INSTALLATION CONSIDERATIONS
Twisted Pair Cable type
- Category 3 or better unshielded twisted pair
Twisted Pair Distances
- rom node to hub 400 ft. (122 m)
- Total network span up to 4,400 ft. (1342 m)
- Maximum of 10 active hubs may be between any two nodes on the network
Mounting
- 19" EIA rack mountable
- wall mountable
- stackable (up to 4 hubs)
CONFORMS TO THE FOLLOWING STANDARDS
|
ARCNET:
|
ANSI 878.1
|
|
EMC:
|
EN55022:1994 (Emissions)
|
|
CISPR 22 1993-12 Class A
|
|
FCC Part 15 Class A
|
|
Safety:
|
EN 60950:1992/A1:1993
|
|
IEC 950:1991+A1:1992+A2:1993
|
|
UL 1950, cUL (CSA 950 accepted equivalent)
|
Before any unit can leave the factory, an intensive elevated temperature burn-in procedure is performed. Our
workmanship and quality control is focused on the goal of customer satisfaction.
Catalogue entry
|