X.25 Gateway for QNX 4
Introduction
CorLink X.25 is an X.25 protocol communications package developed by Corman
Technologies Inc. With CorLink X.25 installation, configuration, and data transfer using
the X.25 protocol is easy.
If, in your QNX environment, you need to support incoming and/or outgoing
communications using the X.25 protocol; if you need to maintain a direct connection to
another QNX network; if you need to communicate via the X.25 Public Data network; or if
you have transaction processing applications that require X.25 communications, CorLink
X.25 is a proven solution.
Typical Applications for CorLink X.25
- Network Connection
- Remote Dial-in through a PAD
- Database Access
- Public Data Network Access
- Remote Process Monitoring
- Financial Transaction Processing
What is CorLink X.25?
The CorLink X.25 Gateway software consists of two main applications: HOST and ITI
(Interactive Terminal Interface). With these two applications, you can connect to and
communicate over X.25 networks worldwide. The applications allow you to share all
available X.25 circuits as they are needed.
HOST
The CorLink X.25 HOST program allows remote users to log into your QNX Network through
the standard device interface.
ITI
The CorLink X.25 ITI (Interactive Terminal Interface) program acts as a Packet
Assembler/Disassembler (PAD) to allow you to make outgoing calls. Like HOST, this is also
accomplished through the standard device interface.
If you need to develop a custom X.25 communications application, the CorLink X.25 API
Toolkit allows you to build complete X.25 support into your QNX applications quickly and
easily. Additional information for the CorLink X.25 API Toolkit is available from Corman
Technologies Inc.
All CorLink X.25 applications depend on the ADMIN process to interface to the
EiconCard.

Features and Benefits of CorLink X.25 V4.2
Both HOST and ITI have an idle timer which can be set to clear X.25 sessions that remain
inactive for a specified amount of time.
This allows you to automatically recover virtual circuits assigned to connections
that may have been terminated incorrectly, also minimizing connections costs.
- ITI supports the 1988 CCITT international PAD parameters.
CorLink X.25's adherence to international standards ensures the highest degree of
compatibility worldwide.
-
HOST detects alteration of its parameters and sends an appropriate 'set PAD parameter'
message to the remote PAD. The parameters sent are usually the CCITT 1988 PAD parameters,
but you can define alternate parameters for special applications.
This allows you to customize HOST for special networks or PADs.
-
HOST can be configured to initialize its tty settings to any specified values. Different
tty setting can be specified for different callers.
This permits you to tailor the tty settings for callers from different sources.
-
CorLink X.25 features full communication tracing including collecting X.25 Packet Level
and HDLC Link Level trace data. You can also use selective traces to collect data on only
particular packet types (such as call cleared, call request, etc.)
The trace functions are useful in troubleshooting problems on your X.25 link.
- The Control Panel (user interface) provides circuit status and clearing facilities.
This allows you to monitor communications and hang up any circuits mistakenly left
active.
-
CorLink X.25 gathers X.25 statistics which you can review at any time. These statistics
include the number of packets sent and received, number of incoming and outgoing calls,
etc.
These X.25 statistics are helpful in analysing the traffic patterns on your X.25
link.
- HOST and ITI provide accounting information in the etc/acclog file.
This allows you to maintain records of all incoming and outgoing X.25 calls
automatically.
- CorLink X.25 allows you to configure your EiconCard as either DCE or DTE.
This permits back-to-back connection of two systems which is often used during
testing.
- CorLink X.25 provides two levels of configuration -- Basic and Plus.
With the Basic configuration you can quickly set the most commonly changed
parameters and get CorLink X.25 up and running fast. The Plus configuration provides
access to all the X.25 parameters (such as link and packet level timers, extended window
sizes, etc.).
- The CorLink X.25 Control Panel is fully QNX network compatible.
You can control CorLink X.25 from any node on the network.
-
HOST and ITI do not have to run on the same network node where the EiconCard is
installed. You can also use multiple HOST's and ITI's with a single EiconCard.
This allows you to use the resources of several computers to handle incoming and
outgoing calls.
The CorLink X.25 Control Panel
The CorLink X.25 Control Panel allows you to configure CorLink X.25 for your
environment, start and stop the CorLink X.25 applications, and check on the status of the
applications.
The Control Panel uses a full-screen, pull down menu interface.
Configuring the X.25 communciations card and CorLink X.25 software is made easy with
the CorLink X.25 Control Panel, practical default values, and support documentation.
The CorLink X.25 software also can be operated from the command line, allowing you to
use shell scripts to automate software start-up.
CorLink X.25 Products
CorLink X.25 Basic
CT-L412
- Includes CorLink X.25 HOST and ITI
- Supports up to 32 virtual circuits
- Transmission speeds up to 19,200 baud
- Physical interface supported: RS-232 (V.24)
- Support for EiconCard C20
- Standard Technical Support
CorLink X.25 Plus
CT-L422
- Includes CorLink X.25 HOST and ITI
- Supports up to 254 virtual circuits
- Transmission speeds up to 2,048,000 baud
- Physical interfaces supported: RS-232 (V.24), V.35, X.21
- EiconCard C20, EiconCard S50
- Standard Technical Support
CorLink X.25 API Toolkit
CT-L432
- Includes CorLink X.25 Plus
- CorLink X.25 Watcom C Function Library
- Sample Application Programs
- Test Program
- API Developer's Manual
- Six months Premium Technical Development Support
System Requirements
- QNX 4.21 or later
- 2M RAM
- EiconCard
Technical Specifications
The EiconCard C20 supports baud rates up to 64,000 bps. The EiconCard S50 supports baud
rates up to 2,048,000 bps.
CorLink X.25 HOST and ITI support up to 120 virtual circuits.
CorLink X.25 API Toolkit supports up to 254 virtual circuits per card.
The maximum total number of virtual circuits supported by a single EiconCard is 254.
When two or more of HOST and ITI are run on one EiconCard, the total number of virtual
circuits in use at any one time cannot exceed 254.
With four EiconCards in one computer, running four copies of CorLink X.25, a total of
1016 virtual circuits can be supported in a single computer.
CorLink X.25 Basic supports up to 32 virtual circuits per EiconCard and baud rates up to
19,200 bps.
Catalogue entry
|