PCI 8 Form C Relay Output / 8 Isolated Input Digital Interface
|
SEALEVEL 8011 PLC-16.PCI |

|
| |
The 8011 digital I/O interface provides 8 optically isolated inputs and 8 Form C relay outputs. The inputs protect the PC and other sensitive equipment from spikes and ground loop current that can be generated in industrial environments, while the outputs provide higher current capabilities (up to 2A) and are optimized for 24V operation. Form C relays can be wired for either normally open or normally closed operation.
If your application requires RoHS compliance, order the 8011-RoHS.
Sealevel's SeaI/O Classic software drivers and utilities make installation and operation easy using Windows 98, ME, NT, 2000, XP and Vista operating systems.
Get a jumpstart on your digital I/O development with The Digital I/O Handbook that will provide helpful information that you will use again and again. Check out Chapter 1 for an overview of logic principles.
|
|
| Technical Specifications |
| Number of I/O
|
8 Inputs
|
| 8 Outputs
|
| Power Requirement |
+5V @ 380mA
|
| Input Range |
5-30 VDC
|
| Input Isolation |
300V
|
| Max. Contact Voltage |
60 VDC/VAC
|
| Max. Contact Current |
2A
|
| Connector |
DB-44F
|
| Operating Temperature |
0 - +70°C
|
| Storage Temperature |
-50° - +105°C
|
| Humidity Range |
10 - 90% R.H.
|
Features:
- Eight Form C relay outputs (SPDT)
- Eight optically isolated inputs optimized for +24V
- Multiple adapters can reside in the same computer
- SeaI/O Classic software supports Windows 98, ME, NT, 2000, XP and Vista operating systems
- Software support for DOS, Linux, Windows 3.1 and Windows 95 available
Catalogue entry
|
|
|
|