PROFIBUS-FMS
PROFIBUS-FDL
PROFIBUS-DP Master
PROFIBUS-DP Slave
  • All PC card formats
  • All leading fieldbus systems
  • Identical ‘easy to use’ APF as on CIFs and on the EC1
  • Direct access to the process data in the dual-port memory
  • One configuration and diagnostic tool
  • Online diagnostic interface
  • LED status display
  • FLASH memory for the configuration data
CIF PROFIBUS

Description:

IPROFIBUS is a Multi-Master System and makes possible the mutual operation of several automation, engineering or visualizing systems at a Bus. The Masters, also designated as active devices, define the data traffic on the Bus. When in possession of the access permission (Token), they can send data without external requests. The Slaves, designated as passive devices, have no Bus access permission. They can only confirm received messages or send messages when requested by a Master. Baud rates from 9.6 kBaud up to 12 MBaud are supported. A maximum of 126 devices can be operated at the Bus. PROFIBUS also supports Broadcast and Multicast communication.

PROFIBUS DP

Is the most commonly used profile. It is optimized for speed, efficiency and low connection costs and tailored especially to the communication between automation systems and their decentralized peripherals. The data exchange with the decentralized devices takes place cyclically from a DP Master of Class 1 (DPM1). A DP Master Class 2 (DPM2) deals with engineering, projects or operating devices. They are used for start-up and for maintenance, for configuration and for diagnostics. By means of advanced DP functions according to the DPV1 specification, acyclic write and read functions as well as alarms between Master and Slaves can be transmitted. These data are addressed within the Slave participant via slot number and index. This takes place parallel of the cyclic user traffic of the Master Class 1.

PROFIBUS-FMS

Is designed for communication on the cell level, for instance between PLCs and PCs. FMS offers 40 services for writing and reading variables, storage regions and the object directory, starting and stopping programs, events management and management services. The data exchange can take place cyclically or acyclically, connection-orientated or as a Multicast or Broadcast. All communication objects of an FMS device are entered into the Object Dictionary, OD. It contains descriptions, structure and data type as well as the assignment between the internal device addresses of the communication objects and the designation at the Bus (Index/Name). FMS differentiates static communication objects such as simple variables, fields, structures, storage regions and events. Additional dynamic communications objects can be altered during operation.

PROFIBUS-PA

Uses the PROFIBUS-DP functions for transmitting data or the DPV1 services for parameterising devices in the region of process automation. The physical transmission is carried out in accordance with IEC 1158-2, which also makes possible a power supply to the devices via the network.

Product Overview:

Type FMS DP-
Master
DP-
Slave
Card
Format
Bus
Interface
ASIC Dual-port memory
CIF 30-DPS     X PC ISA SPC3 2 KByte
CIF 30-DPS X X   PC ISA ASPC2 8 KByte
CIF 50 DPS     X PC PCI SPC3 8 KByte
CIF 50-PB X X   PC PCI ASPC2 8 KByte
CIF 60-DPS     X PCMCIA type 2 PCMCIA SPC3 8 KByte
CIF 60-PB X X   PCMCIA type 2 PCMCIA ASPC2 8 KByte
CIF 80-DPS     X Europakarte 3HE PCI EC1 8 KByte
CIF 80-PB X X   Europakarte 3HE PCI EC1 8 KByte
CIF 100-DPM   X   PC PCI ASPC2 8 KByte
CIF 104-DPS     X PC/104 ISA SPC3 8 KByte
CIF 104-DPS-R connector right     X PC/104 ISA SPC3 8 KByte
CIF 104-PB X X   PC/104 ISA ASPC2 8 KByte
CIF 104-PB-R
Connector right
X X   PC/104 ISA ASPC2 8 KByte
CIF 104P-PB   X   PC/104 PCI EC1 8KByte
PMC-DPS     X PMC PCI 3V / 5V Signalig EC1 8KByte
PMC-PB   X   PMC PCI 3V / 5V Signalig EC1 8KByte

Related Products:

Type Article
SYCON-PB System Configurator, single user licence
DRV-TKIT Toolkit for the development of own drivers with C functions library
DRV-COM COM-Interface for Windows 95/98/ME, Windows NT/2000/XP
DRV-WIN Device driver for Windows 95/98/ME Windows NT72000/XP
DRV-LNX Device driver for Linux
DRV-CE Device driver for Windows CE
DRV-OPC OPC Server, sinlge PC licence
CAB-PB PROFIBUS cable
CAB-SRV Service cable

Technical Data:

PROFIBUS-FMS

Read-, write-, event-, information-, status-, identify-, get OD-services.
MMAC, MSAC, MSCY, BRCT, MULT
4 Parallel services
32 Communication references

PROFIBUS-DP Master

Max. 125 Slaves
Max. 244 byte per Slave

PROFIBUS-DP Slave

Max. 244 byte input
Max. 244 byte output
Total max. 368 byte

PROFIBUS Interface

RS485, optically isolated
DSub-female connector 9-pin
Square post 10-pin angled \P \H
Square post 10-pin straight \S \V
EN 50170

Transmission Rate

9,6 kBuad to 12 MBaud

Diagnostic Interface

RS232C, non-isolated
DSub-male connector 9-pin
Square post 10-pin angled \P
Square post 10-pin straight \S
Square post 16-pin angled \H
Square post 16-pin straight \V

Operating Voltage

5V +5% / 650mA
+12V +5% / 50mA CIF 30 / CIF 50
-12V +5% / 50mA CIF 30 / CIF 50
5V +5% / 300mA CIF 80
3,3V +5% / 500mA CIF 80
5V +5% / 50mA CIF 104P
3,3V +5% < 400MA
3,3V +5% / 600mA PMC
5V +5% / 600mA

Operating Temperature

0°C - ..+55°C

Dimensions (L x W x H)

134mm x 107mm x 20mm CIF 30
134mm x 107mm x 20mm CIF 50
90mm x 55mm x 5,5mm CIF 60
90mm x 96mm x 23mm CIF 104

CE Sign

Catalogue entry

 