| The Communication Interface as a Master on the DeviceNet network exchanges independently the
data between the devices on the bus and the internal process image. The process image is held in the
dual-port memory and the application can access the data directly.
The configuration is carried out with the aid of our System Configurator SyCon® or directly from the
application program. It is stored in the device and is available immediately at the start time.
The Slave devices are configured by the Master via the DeviceNet network. With it only the relevant data in
the process image is passed to or is taken from theapplication.
|
| |
|
| |
| Facts |
| Execution of the DeviceNet protocol stack without load of the PC
|
| Direct access to the process data in the dual-port memory
|
| Easy diagnostic via LED status display
|
| Configuration data is stored in internal FLASH memory
|
| Graphic System Configurator with unified 'look and feel' for all fieldbus systems
|
| Identical 'easy-to-use' application interface on all Communication Interfaces
|
| Device driver for Windows® and Linux included
|
| OPC server available |
| |
| Product |
CIF 60-DNS |
| Description |
Communication Interface PCMCIA |
| DeviceNet-Slave |
| In scope of delivery |
C functions library DRV-TKIT |
| COM interface DRV-COM |
| Device driver Windows DRV-WIN |
| Device driver Linux DRV-LNX |
| Documentation on CD CD-SYS |
| Basic version System Configurator |
| Related products |
Device driver Windows CE DRV-CE |
| SoftPLC-Kit |
| OPC-Server SRV-OPC |
| Card format |
PCMCIA Type 2 |
| Bus Interface |
PCMCIA |
| Dual-port memory |
8 KByte |
| DeviceNet Interface |
| Transmission rate |
125 kBaud, 250 kBaud, 500 kBaud |
| Controller |
SJA 1000 |
| Interface |
ISO 11898, optically isolated |
| Connector |
COMBICON 5-pin |
| Display |
RDY, RUN, NET, MOD |
| Operating voltage |
5 V +5% / 650 mA |
| +11 - 25 V / 55 mA |
| Operating temperature |
0 °C - 55 °C |
| Dimensions (L x W x H) |
86 x 54 x 5 mm |
| Weight approx. |
90 g |
| CE sign |
Yes |