The Communication Interface as an Adapter on the ControlNet network exchanges independently
the data between the devices on the bus and the internal process image. The process image is held in the
dual-port memory and the application can access the data directly.
The configuration is carried out with the aid of our System Configurator SyCon® or directly from the
application program. It is stored in the device and is available immediately at the start time.
Execution of the ControlNet protocol stack without load of the PC
Direct access to the process data in the dual-port memory
Easy diagnostic via LED status display
Configuration data is stored in internal FLASH memory
Graphic System Configurator with unified 'look and feel' for all fieldbus systems
Identical 'easy-to-use' application interface on all Communication Interfaces
Device driver for Windows® and Linux included
OPC server available
Product
CIF 104-CNS
Option
Connector
2x BNC
Square post 10-pin angled | \P
Square post 10-pin straight | \S
Square post 16-pin angled | \H
Square post 16-pin straight | \V
Description
Communication Interface PC/104
ControlNet-Adapter
In scope of delivery
C functions library DRV-TKIT
COM interface DRV-COM
Device driver Windows DRV-WIN
Device driver Linux DRV-LNX
Documentation on CD CD-SYS
Basic version System Configurator (sufficient for the configuration)